In-Slab Underfloor Heating Cable

In-Slab Underfloor Heating Cable

For in-concrete heating across large surface areas

Overview

WIPE hotwire In-Slab Underfloor Heating Cable is engineered for in-concrete heating across large surface areas, featuring a multi-strand heating conductor and a high-temperature outer jacket to withstand embedding in concrete slabs.

Region

Features & Specifications

Click a tab to view the key features or the full construction and technical specifications.

  • Multi-strand heating conductor, tin-plated copper return and earth conductors
  • ETFE insulation, polyester-laminated aluminium foil shielding
  • High-temperature PVC outer jacket, 0.275-inch cable diameter
  • 6.6W/ft. linear wattage, 240V 60Hz
  • 1.64 ft mesh width, 19 W/Sq ft heat density, 3.5 inch cable spacing
  • Cold tail 10 to 15 ft., integrated and separate connection types
  • cUL Listed, metallic fixing strip friendly, suitable for indoor heating

Applications

  • In-concrete heating across large surface areas
  • Suitable for indoor heating

Certifications & Approvals

cUL
Metallic fixing strip fr…
Suitable for indoor heat…

Frequently Asked Questions

What is an in-slab underfloor heating cable?

An in-slab underfloor heating cable is an electric heating solution designed to be installed within concrete floor structures. WIPE hotwire's cable is designed for concrete floors, basement floors, and slab heating applications.

Where can an in-slab heating cable be used?

WIPE hotwire in-slab heating cables are designed for concrete floor heating, basement floor heating, and other indoor underfloor heating applications where the heating cable is integrated into the slab.

What is the heat output of the WIPE hotwire in-slab heating cable?

The in-slab underfloor heating cable provides a linear output of 5.6 W/ft at 240V and 60Hz, with a heat density of 19 W/sq.ft.

What are the key features of the in-slab underfloor heating cable?

The cable features a multi-strand heating conductor, ETFE insulation, polyester-laminated aluminum foil shielding, a high-temperature PVC outer jacket, and a 0.275-inch cable diameter. It is available with metallic fixing strip, FG mesh, and cross filament tape mat variants.

Is the WIPE hotwire in-slab underfloor heating cable suitable for indoor heating?

Yes. The in-slab underfloor heating cable is designed for indoor heating applications and is cUL Listed, with configurations suitable for concrete floor and slab installations.

Have a Specific Requirement?